Model |
S-250-5 |
S-250-7.5
|
S-250-12 |
S-250-15 |
S-250-24 |
S-250-30 |
S-250-48 |
DC output voltage |
5V |
7.5V
|
12V |
15V |
24V |
30V |
48V |
Output voltage range(Note:2) |
±2% |
±2%
|
±1% |
±1% |
±1% |
±1% |
±1% |
Rated output current |
40A |
30A
|
18A |
15A |
10A |
8A |
5A |
Output current range |
0-40A |
0-30A
|
0-18A |
0-15A |
0-10A |
0-8A |
0-5A |
Wave and noise(Note:3) |
150mVp-p |
200mVp-p
|
150mVp-p |
150mVp-p |
180mVp-p |
180mVp-p |
240mVp-p |
Inlet stability(Note:4) |
±0.5% |
±0.5%
|
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±1% |
Load stability(Note:5) |
±1% |
±1%
|
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±1% |
DC output power |
200W |
225W
|
216W |
225W |
240W |
240W |
240W |
Efficiency |
78% |
80%
|
82% |
83% |
85% |
85% |
87% |
Adjustable range for DC voltage |
4.5~5.8V |
6~9V |
10~14V |
12~18V |
120~28V |
27~233V |
41~56V |
Input current |
5A/115V 2.5A/230V
|
||||||
AC inrush current |
18A/115V 36A/230V
|
||||||
Leakage current |
<3.5mA/240VAC
|
||||||
Overload protection |
105%~150% Type: pulsing hiccup shutdown Reset: auto recovery
|
||||||
Over-voltage protection |
6~7V
|
9.4~10.9V |
14.4~16.8V |
18.5~21.5V |
31.2~36V |
34.5~40.5V |
57.6~67.2V |
High-temperature protection |
ERH3>=65~70°c Fan on, <=55~60°c Fan off,>=80~85°c, Cut off ouput(5~15V)~(24~48V) |
||||||
Setup, rise , hold up time |
1ms,20ms, 20ms
|
||||||
Vibration |
10~500Hz, 2G 10min,/1cycle, Period for 60min, Each axes
|
||||||
Withstand voltage |
Input and output internal: 1.5KvAC, Input and enclosure:1.5KvAC, Output and enclosure:0.5KvAC |
||||||
Working temperature and humidity |
-10°c~+60°c(Refer to output derating curve), 20%~90%RH |
||||||
Weight |
1.1Kgs
|
||||||
Safety standards |